Heat & Glo LifeStyle BAY-40 Indoor Fireplace User Manual


 
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07
25
2 in. (51 mm) min.
4-1/2 in.
(114 mm)
max.
1-1/2 in.
(38 mm) min.
overlap
Cap Standoff
Top of Pipe
Flashing Collar
Figure 6.7 Installing an ST1175 Square Termination Cap
The last section of pipe
must stop between the
distances given below.
2 in. (51 mm) above top
of the chase.
7 in. (178 mm) below top
of the chase.
{
Top of Pipe
1-1/2 in. (38 mm)
min. overlap
Figure 6.8 Installing a TCT1175 Terra Cotta Cap
For installations utilizing an ST1175 Square Termination
Cap the last chimney section must not be more than
4-1/2 in. (114 mm) below the chase top. See Figure 6.7.
For installations utilizing an TCT1175 Terra Cotta Cap the
last chimney section must be between 7 in. (178 mm) below
the chase top and 2 in. (51 mm) above. See Figure 6.8.
For chase installations you can use a TR11 Round
Termination Cap, a TR11T Round Telescoping Termination
Cap, an ST1175 Square Termination Cap, or a TCT1175
Terra Cotta Termination Cap.
For installations utilizing a European Copper Series
Termination Cap, See Figure 6.9.
Install termination caps following instructions provided
with them.
chimney top
2 - 6 in.
(51-152 mm)
2 in. (51 mm)
typical
chase
top
(metal or masonry)
Cap Base
(cap inner flue)
SL pipe
inner flue
screw (8)*
bracket (8)
Figure 6.9 Installing a European Copper Series Termination Cap
(CT3-King shown)