D. Flue Damper
The ue damper must be in full open position, and is oper-
ated by moving the handle up toward the top of the replace.
Before lighting the re, verify this by looking up from the in-
side of the replace. Always operate this replace with the
damper fully open. Please note: Down drafts, obstructions,
damaged or poor (wet) fuels can cause smoke spillage.
See Figure 9.1 for location and operation.
PARTLY OPEN
INCORRECT
FULLY OPEN
CORRECT
PARTLY CLOSED
INCORRECT
FULLY CLOSED
CORRECT
Figure 9.2 Proper Operating Positions of Bi-fold Doors
Fire Risk
Close rescreen when burning replace.
Do not use rescreen or glass doors to
hold burning material in replace.
Firescreen controls sparks.
Glass may break or burning material may
roll out.
WARNING
Fire Risk
Smoke Risk
Doors must be fully opened or fully closed
when operating replace.
Partially opened doors may draw ame, smoke
or heat from replace.
WARNING
Asphyxiation Risk
Fire Risk
Open damper to operate replace.
Closed damper will over- re replace and
prevent venting of combustion gases.
WARNING
B. Outside Air
A source of air (oxygen) is required in order for combustion
to take place. Whatever air is consumed by the re must be
replaced through cracks around windows, under doors, etc.
Most newly constructed houses or existing homes tted with
tightly sealed doors and windows are relatively air tight. In
this case, an outside air source must be made available to
feed combustion air from outside the home.
An outside air control handle allows you control of the out-
side air inlet if your replace is equipped with this option.
Use of outside air for combustion is highly recommended to
conserve heated air within the structure and to provide make
up air to keep the replace venting properly.
This replace will operate correctly only if adequate ventila-
tion is provided to allow proper draft to the replace sys-
tem.
See Figure 9.1 for location and operation.
CAUTION
Outside air control handle is HOT. Adjust before lighting
re.
C. Clear Space Near the Fireplace
Combustible materials must not be stored on the hearth ex-
tension. Room furnishings such as drapes, curtains, chairs
or other combustibles must be at least 4 ft (1.22 m) from the
open front of the replace.
E. Firescreen
A rescreen is always provided to control sparks. It must
be closed whenever the replace is in use. Glass doors or
rescreens must not be used to hold burning material in-
side the replace. Only those glass doors speci cally tested
and listed for use with the speci c replace model should be
used. Screens should be closed when the glass doors are
closed.
F. Glass Doors
Most ef cient replace operation using glass doors is with
the doors open. When the doors are open the screen must
be closed. Only Hearth & Home Technologies glass doors
may be used. See Figure 9.2 for proper glass door opera-
tion.