Diagnostic Questions Possible Causes of Condition Solutions
Do you have glass doors? Need to slow air intake Add glass doors.
What is the condition of the
wood?
Extremely dry wood Mix in less seasoned wood after re established.
Diagnostic Questions Possible Causes of Condition Solutions
Does the re start and burn
well?
No:
Damper not fully open Open damper; check and clean chimney if needed; use adequate
kindling and fuel; open glass doors or open window, check for
need for balanced air make-up.
Chimney obstruction
Not enough kindling and/or fuel to establish
draft
Inadequate combustion air
Yes:
Fire too close to front Build re farther back. Do not use exhaust fans during startup
and/or check for need for balanced air make-up system.
Competition with exhaust devices
Diagnostic Questions Possible Causes of Condition Solutions
Is the damper closed? No: Down draft or negative pressure Close the damper at end of burn.
Yes: Negative pressure from exhaust fans
and/or house stack effect.
Check for need for glass doors. Check for need for balanced air
make-up system or raising chimney.
Is the chimney clean? No: Creosote odor Have chimney cleaned.
Yes: Damper closed too early Wait until re completely out before closing damper.
I smell smoke in the house during operation. What’s causing that?
I smell smoke in the house after we’ve had a re in the replace. What is the cause/what can we do?
The replace burns the wood too fast. What can I do?