Figure 7.8 Flue Components and Terminations
MODEL
SOHO-N-AUB
FLUE TERMINATION APPROVALS
SLP-TRAP2 HORIZONTAL TERMINATION CAP
SLP-TVHW VERTICAL TERMINATION CAP
DVP-FBHT HORIZONTAL TERMINATION CAP
Flue System Approvals And Installations
These models have ue starting collars on both the top
and the back of the unit. Depending upon the installation,
decide which ONE set of starting collars will be used to at-
tach the ue system. The starting collar sealing cap must
remain on the starting collar NOT used.
These models use SLP series direct ue components.
Approved ue system components are labeled for identi-
cation. NO OTHER FLUEING SYSTEMS OR COMPO-
NENTS MAY BE USED. Detailed installation instructions
are included with each ue termination kit and should be
used in conjunction with this manual. Figure 7.8 shows
ue system components and terminations.
Identifying Flue Components
The ue systems installed on this gas replace may include
one, two, or three 90°
elbow assemblies. The relationships
of vertical rise to horizontal run in ue congurations using
90° elbows MUST BE strictly adhered to. The rise to run
relationships are shown in the ueing drawings and tables
on the next few pages.
WARNING! Risk of Fire! This gas appliance and ue as-
sembly must ue directly to the outside and must never
be attached to a chimney serving a separate solid fuel
burning appliance. Each gas appliance must use a sepa-
rate ue system-common ue systems are prohibited.
WARNING! Risk of Fire! DO NOT apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as specied in
this manual. Overlapping material could ignite and will in-
terfere with proper operation of doors and louvers.
Horizontal sections 3 in. (76 mm) from the top of the
pipe.
Horizontal sections 2-1/2 in. (64 mm) at wall shield
restops.
Horizontal sections 1 in. (25 mm) from sides and bottom
of the pipe.
Vertical sections 1 in. (25 mm) on all sides of pipe.
Failure to keep insulation or other material away from
vent pipe may cause over heating and re.
For alternative installations, other than depicted, contact
your dealer for further information.
HORIZONTAL
TERMINATION
WALL FIRESTOP
90 DEGREE
ELBOW
VERTICAL
TERMINATION
STORM COLLAR
ROOF FLASHING
HORIZONTAL PIPE
SUPPORT
PIPE LENGTH
WALL BRACKET
CEILING
FIRESTOP
SLP-TVHW
SLP-TRAP2
SLP SERIES
Flue system termination kits
DVP-FBHT