Heat & Glo LifeStyle 2197-980 Indoor Fireplace User Manual


 
27
Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12
Top Vent - Horizontal Termination - (continued)
Figure 7.5
Three Elbows
V
1
Minimum H
1
Maximum V
2
Minimum H
2
Maximum
6 in. 152 mm 1 ft. 305 mm 1 ft. 305 mm 1 ft. 305 mm
1 ft. 305 mm 2 ft. 610 mm 2 ft. 610 mm 2 ft. 610 mm
2 ft. 610 mm 2 ft. 610 mm 3 ft. 914 mm 4 ft. 1.22 m
3 ft. 914 mm 3 ft. 914 mm 4 ft. 1,22 m 6 ft. 1.83 m
4 ft. 1.22 m 4 ft. 1,22 m 5 ft. 1,52 m 8 ft. 2.44 m*
5 ft. 1.52 m 6 ft. 1,83 m 6 ft. 1,83 m 12 ft. 3.66 m
*H
1
= 6 ft. (1.83 m) Maximum *H
1
+ H
2
= 12 ft. (3.66 m) Maximum
V
1
+ V
2
= 32 ft. (9.75 m) Maximum V
1
+ V
2
+ H
1
+ H
2
= 36 ft. (10.97 m) Maximum
USE SLP SERIES COMPONENTS ONLY
Note: A 6 in. (152 mm) section of straight ue must be
attached to the replace before a 90° elbow.
H
1
V
2
H
2
V
1