Heat & Glo LifeStyle 2197-980 Indoor Fireplace User Manual


 
Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/1216
B. Maintenance Tasks-Qualied Service
Technician
To prevent inadvertent burner operation while servicing
this appliance:
• Unplug DC regulator from junction box.
• Remove batteries from battery pack (if installed).
• Shut off gas supply to the appliance.
The following tasks must be performed by a qualied ser-
vice technician.
Gasket Seal and Glass Assembly Inspection
Frequency: Annually
By: Qualied Service Technician
Tools needed: Protective gloves, drop cloth and a stable
work surface.
• Inspect gasket seal and its condition.
• Inspect xed glass assembly for scratches and nicks that
can lead to breakage when exposed to heat.
• Conrm there is no damage to glass or glass frame.
Replace as necessary.
• Verify that xed glass assembly is properly retained and
attachment components are intact and not damaged.
Replace as necessary.
Logs
Frequency: Annually
By: Qualied Service Technician
Tools needed: Protective gloves.
• Inspect for damaged or missing logs. Replace as neces-
sary. Refer to Section 14.E for log placement instructions.
• Verify correct log placement and no ame impingement
causing sooting. Correct as necessary.
Firebox
Frequency: Annually
By: Qualied Service Technician
Tools needed: Protective gloves, sandpaper, steel wool,
cloths, mineral spirits, primer and touch-up paint.
• Inspect for paint condition, warped surfaces, corrosion
or perforation. Sand and repaint as necessary.
• Replace replace if rebox has been perforated.
Control Compartment and Firebox Top
Frequency: Annually
By: Qualied Service Technician
Tools needed: Protective gloves, vacuum cleaner, dust
cloths
• Vacuum and wipe out dust, cobwebs, debris or pet hair.
Use caution when cleaning these areas. Screw tips that
have penetrated the sheet metal are sharp and should
be avoided.
• Remove all foreign objects.
• Verify unobstructed air circulation.
Gas Pressure Information
Frequency: Upon initial installation and gas valve re-
placement or service.
By: Qualied Service Technician
Tools needed: Protective gloves, manometer, ashlight,
screw driver set.
• Gas pressure taps are accessible by removing the deco-
rative front and xed glass assembly. Refer to section
11.A for information related to the gas valve and gas
pressure settings.