Hearth and Home Technologies PIER-HVB-CE Indoor Fireplace User Manual


 
Heat & Glo • PIER/ST/L&RCOR-HVB-CE • 2068-900 Rev. H • 6/0722
Figure 11. Flueing with One 90° Elbow
Figure 10. Flueing with One 90° Elbow
V
H
H
V
NATURAL GAS - FLUEING WITH ONE 90° ELBOW
V (FT.) H (FT.)
1' MIN. (305mm) 3' MAX. (914mm)
2' MIN. (610mm) 6' MAX. (1.83m)
3' MIN. (914mm) 9' MAX. (2.7m)
4' MIN. (1.22m) 12' MAX. (3.6m)
5’ MIN. (1.5m) 15’ MAX. (4.5m)
6’ MIN. (1.83m) 18’ MAX. (5.5m)
V + H = 40’ MAX. (12.2m)(11.3m)
PROPANE / BUTANE - FLUEING WITH ONE 90° ELBOW
V (FT.) H (FT.)
1' MIN. (305mm) 2' MAX. (610mm)
2' MIN. (610mm) 4' MAX. (1.22m)
3' MIN. (914mm) 6’ MAX. (1.83m)
4' MIN. (1.22m) 8' MAX. (2.4m)
5’ MIN. (1.5m) 10' MAX. (3.0m)
6’ MIN. (1.83m) 12’ MAX. (3.6m)
V + H = 40’ MAX. (12.2m)
NATURAL GAS
FLUEING WITH ONE 90° ELBOW
V (FT.) H (FT.)
1' MIN. (305mm) 3' MAX. (914mm)
2' MIN. (610mm) 6' MAX. (1.83m)
3' MIN. (914mm) 9' MAX. (2.7m)
4' MIN. (1.22m) 12' MAX. (3.6m)
5’ MIN. (1.5m) 15’ MAX. (4.5m)
V + H = 40’ MAX. (12.2m)
PROPANE / BUTANE
FLUEING WITH ONE 90° ELBOW
V (FT.) H (FT.)
1' MIN. (305mm) 2' MAX. (610mm)
2' MIN. (610mm) 4' MAX. (1.22m)
3' MIN. (914mm) 6’ MAX. (1.83m)
4' MIN. (1.22m) 8' MAX. (2.4m)
5’ MIN. (1.5m) 10' MAX. (3.0m)
V + H = 40’ MAX. (12.2m)