Hearth and Home Technologies GBI25 Indoor Fireplace User Manual


 
02-02 15 26678 Rev H
GBI25 SERIES B-VENT GAS FIRED FIREPLACE INSERT
1. OPERATION PROCEDURE DURING
REGULAR USE
Turn the switch/thermostat to the ON position. This
will ignite the main burner.
2. SHUTDOWN DURING REGULAR USE
Simply turn the switch/thermotat to OFF. This will
disengage the burner and the flames will extinguish.
3. SEASONAL SHUTDOWN
When the burning season comes to an end, the entire
system should be shut down to prevent gas running
to the appliance while it is not in use.
4. FAN OPERATION
The fan control is located behind the control access
panel. Lift the panel up and rotate forward. Locate the
fan control knob and turn. See Figure 18. Close the
control access panel.
5. CHECKING FLAME PATTERNS
Check the flame pattern of the burner periodically,
making sure the flames are steady, not lifting or
floating. The flame color should be blue with yellow
tips. The thermopile tip should be covered with flame.
See Figures 26 and 27.
If the vent configuration is installed incorrectly, the vent
may cause the flames inside the appliance to lift or
ghost - a dangerous situation. Inspect the flames
after installation to ensure proper performance. If the
vent configuration is correct, yet the flames are lifting
or ghosting, shut off gas to the appliance and contact
the dealer for information on remedying the problem.
Note: If the air shutter is open all the way and the flames
remain sooty, shut off gas to the appliance and contact
a qualified service technician.
WARNING!
Children and adults should be alerted to the hazards
of high surface temperatures and should stay away
to avoid burns or clothing ignition. Young children
should be carefully supervised when they are in the
same room as the appliance.
Figure 26 - Standing Pilot
Figure 27 - Flame Patterns