Hearth and Home Technologies GBI25 Indoor Fireplace User Manual


 
02-02 11 26678 Rev H
GBI25 SERIES B-VENT GAS FIRED FIREPLACE INSERT
h. Firebox Bottom Removal
1) Shut off the gas to the appliance before
removing. Remove the glass frame following
instructions found in Step 3a. on page 7.
2) Remove the two screws on the log assembly
(Figure 20). Pull out the log assembly (Figure
21) and place in a safe area. Remove the
four screws located around the firebox
bottom. See Figure 22.
3) To re-install the firebox bottom, reverse the
above steps.
Figure 20 - Log Assembly Removal
Figure 21 - Log Assembly Removal
Figure 22 - Firebox Bottom Removal
Figure 23 - Fan Removal
i. Fan Access
1) Disconnect the power cord or turn off the
circuit breaker before removing the fan.
Remove the firebox bottom following
directions in Step 3h.
2) Remove the four screws located on the fan
bracket (Figure 23). Remove two on the fan
control. Remove the bushing and unplug the
cord from the junction box. Slide the fan
bracket out.
3) To re-install fan, reverse the above steps.
WARNING!
Any safety screen or guard removed for servicing an appliance must be replaced prior to operating this appliance.
Clothing or other flammable material should not be placed on or near the appliance.