Symptom Possible Cause Corrective Action
4. Pilot lights but contin-
ues to spark, and main
burner will not ignite.
(If the pilot continues
to spark after the
pilot ame has been lit,
ame recti cation has
not occurred.)
A. A shorted or loose connection in ame
sensing rod.
Verify all connections to wiring diagram in manual. Verify
connections underneath pilot assembly are tight. Verify con-
nections are not grounding out to metal chassis, pilot burn-
er, pilot enclosure or screen if present, or any other metal
object.
B. Poor ame recti cation or contaminated
ame sensing rod.
With xed glass assembly in place, verify that ame is en-
gul ng ame sensing rod on left side of pilot hood. Flame
sensing rod
should glow shortly after ignition. Verify cor-
rect pilot ori ce is installed and gas inlet is set to pressure
speci cations. Clean ame sensing rod with emery cloth to
remove any contaminants that may have accumulated on
ame sensing rod.
C. Module is not grounded. Verify module is securely grounded to metal chassis of ap-
pliance. Verify that wire harness is rmly connected to the
module.
D. Damaged pilot assembly or contami-
nated ame sensing rod.
Verify that ceramic insulator around the ame sensing rod
is not cracked, damaged, or loose. Verify connection from
ame sensing rod to white sensor wire. Clean ame sensing
rod with emery cloth to remove any contaminants that may
have accumulated on ame sensing rod. Verify continuity
with a multimeter with ohms set at lowest range. Replace
pilot if any damage is detected.
E. Module. Turn ON/OFF rocker switch or wall switch to OFF position.
Remove ignitor wire “I” from module. Place ON/OFF rocker
switch or wall switch in ON position. If there is no spark at “I”
terminal module must be replaced. If there is a spark at “I”
terminal, module is ne.