Hearth and Home Technologies 6000G-IPILP Indoor Fireplace User Manual


 
Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. O • 12/08 29
Figure 7.12
Top Vent - Vertical Termination - (continued)
Three Elbows
INSTALLED
HORIZONTALLY
H
1
H
2
V
1
V
2
V
1
H
1
+ H
2
V
2
V
1
+ V
2
Minimum H
1
+ H
2
Maximum
Elbow only 1 ft. 305 mm * * * 1 ft. 305 mm
6 in. 152 mm 2 ft. 610 mm * * * 2 ft. 610 mm
1 ft. 305 mm 2 ft. 610 mm * * * 2 ft. 610 mm
2 ft. 610 mm 4 ft. 1.2 m * * * 4 ft. 1.2 m
3 ft. 914 mm 9 ft. 2.7 m * * * 9 ft. 2.7 m
4 ft. 1.2 m 18 ft. 5.5 m * * * 18 ft. 5.5 m
H
1
+ H
2
= 20 ft (6.1 m) Maximum V
1
+ V
2
+ H
1
+ H
2
= 40 ft (12.2 m) Maximum