Hearth and Home Technologies 6000G-IPILP Indoor Fireplace User Manual


 
Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. O • 12/08 57
I. Air Shutter Setting
Air shutter settings should be adjusted by a quali ed ser-
vice technician at the time of installation. The air shutter is
set at the factory for minimum vertical vent run. Adjust air
shutter for longer vertical runs. See Figure 14.15.
• Loosen the wing nut.
• Push the air handle in to close the air shutter.
• Pull the air handle out to open the air shutter.
• Tighten the wing nut.
NOTICE: If sooting occurs, provide more air by opening
the air shutter.
Figure 14.15 Air Shutter
Figure 14.14 Fixed Glass Assembly
G. Fixed Glass Assembly
WARNING! Risk of Asphyxiation! Handle xed glass
assembly with care. Inspect the gasket to ensure it is
undamaged and inspect the glass for cracks, chips or
scratches.
DO NOT strike, slam or scratch glass.
DO NOT operate replace with glass removed, cracked,
broken or scratched.
Replace as a complete assembly.
Removing Fixed Glass Assembly
Pull the four glass assembly latches out of the groove on
the glass frame. Remove glass door from the appliance
(see Figure 14.14).
Replacing Fixed Glass Assembly
• Replace the glass door on the appliance. Pull out and
latch the four glass assembly latches into the groove on
the glass frame.
Air Shutter Settings
NG LP
Burner 1/8 in. Full Open
H. Install Trim and/or Surround
• Install optional trim kits and/or surrounds using the
instructions included with the accessory.
Use non-combustible materials to cover the gap between
the sheet rock and the appliance (when applicable to the
model).
GLASS
ASSEMBLY
LATCHES
(BOTH BOTTOM
AND TOP)
AIR SHUTTER
WING NUT