GE 255 Water Heater User Manual


 
21
2. Press and hold the button for 5 seconds. This
will start the second regeneration.
Quick cycle as Tank 2 moves through cycles:
C5 - Fast Rinse
C6 - 2nd Backwash
C7 - 2nd Rinse
C8 - Regenerant Refill; the aircheck is filled and
flow to the regenerant tank is visable.
Quick cycle to Service
then--
Quick cycle as Tank 1 moves through cycles:
C1 - Backwash
C2 - Regenerant Draw; the regenerant tank
should have water in it. As the draw occurs the
level will go down.
C3 - Slow Rinse
C4 - Standby
At this point Tank 1 is fully operational.
3. Press and hold the button for 5 seconds. This
will start the third regeneration. After this step both
tanks will be ready.
Quick cycle as Tank 1 moves through cycles:
C5 - Fast Rinse
C6 - 2nd Backwash
C7 - 2nd Rinse
C8 - Regenerant Refill
Quick cycle to Service
then--
Quick cycle as Tank 2 moves through cycles:
C1 - Backwash
C2 - Regenerant Draw; the regenerant tank
should have water in it. As the draw occurs the
level will go down.
C3 - Slow Rinse
C4 - Standby
Both tanks are now ready.
4. Turn on a faucet plumbed after the water conditioner.
Run the faucet until the water runs clear.
5. Add water to the regenerant tanks.
A. With a bucket or hose, add water until
approximately 4 gallons (15 liters) of water in
each regenerant tank.
B. If the tank has a salt platform in the bottom of
the tank, add water until the water level is
approximately 1 inch (25 mm) above the
platform.
The Alternating Water Conditioning
System is Now Fully Operational
Note:
After any control reset (valve type or system
change, etc.) it is necessary to initiate a manual
regeneration and quick cycle through it. This will ensure
the control and cam are synchronized. If not synchronized
err# will display and the control will drive cams to the
correct position for valve and system type programmed..