Enviro EG 28 Indoor Fireplace User Manual


 
TROUBLE SHOOTING
Problem Possible Cause Solution
Spark will not light the pilot after
repeated pressing of spark igniter
Defective piezo igniter Check connections to igniter
-If igniter connections are good but
there is no spark-replace igniter
Broken spark electrode -Check for broken ceramic insulation
replace, electrode if broken
Miss-aligned spark electrode -If spark is not arcing from the
electrode to pilot- adjust by loosening
screws on pilot base. Adjust and re-
tighten
Pilot will not remain lit Problem with thermocouple circuit -Check for proper connection of
thermocouple to rear of valve. If
loose, tighten lightly
-Check pilot for full flame
impingement around thermocouple.
If the pilot is to small - Check gas
pressure, adjust pilot rate screw,
check pilot head for blockage.
-Check thermocouple voltage at
valve- must be greater than 5 mV. If
low, replace thermocouple.
Air in gas line - (Pilot flame dies while knob
is depressed.)
-Bleed line.
-Check gas line pressure.
-Contact dealer.
Burners will not remain lit Problem with thermopile circuit -Check gas line pressure.
-Check for flame impingement on
thermopile, if low see “Pilot will not
stay lit”
-Check thermopile for a Minimum of
300 mV when burner switched
on.
-Check wiring to thermostat for
breaks.
Flame lifting Leak in vent pipe
Improper vent configuration
Terminal may be recirculating flue gases
-Check for leaks in vent connections
-Check vent configuration with
manual
-Check to see if terminal is on
correctly
-May need to install high wind
termination cap
-Contact dealer.
Glass fogs up Normal conditions - after the appliance warms up glass will clear
** Due to additives in gas, glass may get hazy during normal use**
Clean when needed.
Blue flames
Normal during start - flame will yellow as the
appliance heats up.
Flames are burning “dirty” or
Sooting
Flame impingement -Check log position
-Increase primary air by opening
venturi shutters
See also “Burners will not stay lit”
17