Enviro EG 28 Indoor Fireplace User Manual


 
PARTS AND ACCESSORIES
Service Parts available from your local Envirogas Dealer
Burner Control Assembly
Natural Gas Pilot Assembly
Propane Pilot Assembly
Door Bolt
Relief Door Gasket
Regulating Valve
Piezo Igniter
Burner Switch
B-vent Spill switch 220°
Orifice Blank
Convection Blower
Light Bulb Holder
Light Switch (momentary)
Fan Controller
Log Set (with Embers)
Thermocouple
Embers
Thermopile
Door Gasket
Convection Fan Sensor 120° (48°C)
Accessories
Gold trim Package
Low Voltage Thermostat
INSTALLING OR REMOVING THE BLOWER
The blower does not require lubrication.
20
1. Turn the unit off and remove the log set.
2. Remove the burner tray assembly by
removing the screw on either side of the
tray, between the front and rear burners.
Lift the tray out.
3. Remove the 4-5/16” bolts that hold the
blower mounting plate to the back firewall.
Use a light lubricating oil on screws before
removal.
4. Carefully pull the assembly into the firebox.
Install the blower onto the mounting
bracket (blower outlets pointing through the
two holes in the bracket) using the 4
screws provided.
5. Connect wires according to the wiring
diagram. (If removing the blower,
disconnect the blower leads from the
harness. Remove the blower.)
6. Check mounting plate gasket and reverse steps 1 through 4.