Enviro EG40-070 Indoor Fireplace User Manual


 
Thermopile
Thermocouple
Figure 4: Gas Valve.
Figure 3: Pilot Burning.
7
There is a separate venturies for each burner,
see Figure 5.
Remove one screw from the cover plate located
below the ash shelf and loosen the other screw
(do not remove) swing the cover plate out of the
way and tighten screw down to hold it in place.
With along screwdriver rotate spring clips to open
or close the venturies to the desired setting.
The venturies allows the amount of air coming into
the replace to be adjusted in order to accommodate
different climates and venting arrangements. Start
Operating Instructions
Gold bar
Screwdriver
Rear log holder
Front log holder
Ember tray &
front burner
Venturies
Door
Rear burner
Air shutter cover plate
Figure 5: Venturi Adjustment.
the pilot and then the burner. Make sure the pilot ame is burning normally and none of the burner ports
are plugged. Let the replace burn for roughly fteen9minutes and then examine the ames, compare
the ames to Figure 16.
The ideal ame will be blue at the base and light orange above. The ames should be of medium height.
If the ames look like this, no venturi adjustment is needed. If the ames are fairly short and mostly blue,
the replace is getting too much air. Therefore, the venturies should be closed slightly until the correct
ames are achieved. Flames that are very orange, with tall, dark, stringy tips, are not getting enough air.
Open the venturi until the ames clean up. If the venturi is opened, or closed all the way, and the correct
ames cannot be attained, turn off the gas and contact the dealer.
Warning: Incorrect venturi adjustment may lead to improper combustion, which is a safety hazard.
Contact the dealer if there is any concern about the venturi adjustment.
NORMAL SOUNDS DURING OPERATION:
Table 1: Normal Sounds
Component Sound & Reason
EG40 Creaking when heating up or cooling down.
Burner Light pop or poof when turned off; this is more common with LP units.
Temperature Sensor Clinking when it senses to turn the blower on or off.
Pilot Flame Quiet whisper while the pilot ame in on.
Blower / Fan Air movement that increase and decreases with the speed of the blower. The
blower is pushing the heat from the replace into the room.
Gas Control Valve Dull click when turning on or off, this is the valve opening and closing.
ADJUSTING THE VENTURIES: