PLANNING YOUR INSTALLATION:
When planning your installation, it will be necessary to select the proper length of vent pipe for your
particular requirements. It is important to note when passing through a wall, the maximum allowable
wall thickness is 10 inches (25.4 cm), 1 inches (3.8 cm) clearance to combustibles must be maintained.
Select the amount of vertical rise desired for “vertical-to-horizontal” type installations. To determine
the length of vent pipe required for vertical installations, measure the distance from the appliance ue
outlet to the ceiling, the ceiling thickness, the vertical rise through the attic or second story, and allow
for sufcient vent height above the roof line. For two story applications, a re stop is required at each
oor level. If an offset is needed in the attic, additional pipe and elbows will be required. To connect the
venting system to the appliance ue outlet, a twist-lock adapter is built into the appliance at the factory.
Refer to ‘Vent Conguration and Restrictor Settings’ for venting parameters.
Your total vent pipe length must be within the shaded area of Figure 22. If a 90° elbow is used in the
horizontal plane, 36” (91.4 cm) must be subtracted from the allowable horizontal run.
There are two (2) basic types of Direct Vent System installations; they are shown in Figure 14 and 15.
Figure 14: Common Horizontal Installation.
Figure 15: Common Vertical Installation.
13
Initial Installation
QUALIFIED INSTALLERS ONLY