Enviro EG40-070 Indoor Fireplace User Manual


 
Initial Installation
QUALIFIED INSTALLERS ONLY
WARNING:
Operation of this heater when not connected to a properly installed and maintained venting system can
result in carbon monoxide (CO) poisoning and possible death.
PREPARATION FOR INSTALLATION:
• Remove the packaging from the appliance, and check to make sure there is no damage. If damage is
found, please report it to both the carrier and your dealer as soon as possible.
• Before beginning, carefully check the glass door and the log set
• Locate a position where the ue system of the stove can be properly installed without damaging the
integrity of the building; e.g. cutting a wall or ceiling joist.
• Check stove and ue system clearance requirements.
• Locate the stove where it can be accessed by a gas supply line.
• Locate the stove in a large and open room that is centrally located in the house. This will optimize heat
circulation and comfort.
• As the stove is equipped with a convection fan, ensure that an electrical outlet is within 6 ft (1.8 m) of
the stove.
• The ow of combustion and ventilation air must not be obstructed.
CLEARANCES TO COMBUSTIBLES:
A. Sidewall to unit 12 inches (30.5 cm)
B. Backwall to unit 4 inches (10.2 cm)
C. Corner to unit 2 inches (5.1 cm)
D. Combustibles to unit top 36 inches (91.4 cm)
E. Floor to unit 0 inches (0 cm)
F. Alcove maximum depth: 48 inches (121.9 cm)
CLEARANCES MUST BE SUFFICIENT TO ALLOW ACCESS FOR MAINTENANCE AND SERVICE.

 

 

 
Figure 13: Clearances to combustibles.
12