Enviro EG40-070 Indoor Fireplace User Manual


 
Operating Instructions
FOR YOUR SAFETY READ COMPLETELY BEFORE OPERATING.
LIGHTING INSTRUCTIONS:
6
1. STOP! Read the safety information above on this label.
2. Turn off all electrical power to this appliance.
3. Turn off the gas control knob clockwise to the off position.
4. Open door. Wait fIve (5) minutes to clear out any gas. Close
door. If you smell gas STOP! Follow “B” in the above safety
information. If you do not smell gas go to the next step.
5. Find pilot-located to the right between the front and rear burner.
Turn the gas control knob counter-clockwise to
“PILOT”. Push the gas control in fully and hold, keep knob
depressed for about 30 seconds after the pilot is lit.
Release knob. If pilot goes out, repeat steps 4
through 5.
CAUTION:
Hot while operating. Do not touch, severe burns may result. Keep children,
clothing, furniture, gasoline or other flammable vapors away.
FOR YOUR SAFETY READ BEFORE OPERATING
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY,A FIRE OR EXPLOSION MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
A) This appliance is equipped with a pilot, which must be lit by
hand by following these instructions exactly.
B) BEFORE LIGHTING smell all around the appliance area for
gas and next to the floor because some gas is heavier than air
and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance. Do not touch any electrical
switch: do not use any phone in your building. Immediately call
your gas supplier from a neighbor's phone. Follow the gas
suppliers instructions. If you cannot reach your gas supplier, call
the fire department.
C) Use only your hand to push in or turn the gas control knob;
NEVERuse tools. If the knob will not push in or turn by hand,
do not try to repair it. Call a qualified service technician.
Force or attempted repair may result in a fire or explosion.
D) Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and
any gas controlwhich has been under water.
LIGHTING INSTRUCTIONS
WARNING: this gas valve has a lockout device, which will not
allow thepilot burner to be relit until the thermocouple has
cooled. If the knob doesdoes not pop up when released, stop
and immediately call your service technician or gas supplier.
If the pilot does not stay lit after several tries, turn the gas
control knob to “OFF” and call your service technician or
gas supplier.
6. Turn the gas control knob counter clockwise to the
“ON” position. Flip the burner switch to “ON” THEN TURN
THE “HI/LOW” knob to the
desired setting.
7. Turn on the electrical
power to the unit.
TO TURN OFF GAS TO APPLIANCE
1. Flip burner switch to “OFF”
2. Turn the gas control knob clockwise to the “OFF” position.
3. Turn off all electrical power to the appliance if service is to
be performed.
CAUTION: Do not operate this fireplace with the glass removed, cracked or broken. Replacement of the panel(s) should be done by a
licensed or qualified person! This appliance needs fresh air for safe operation and must be installed with provisions for combustion
and ventilation air. See installation and operating instructions manual. Keep burner and control compartment clean.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage, or loss of life.
Refer to owner's information manual provided with this appliance. For assistance or additional information consult a qualified installer,
service agency or the gas supplier. See installation and operating instructions accompanying appliance. Installation and service must
be performed by a qualified installer, service agency, or the gas supplier.
O
L
I
T
P
TPTH TP TH
IN OUT
H
I
L
O
N
O
F
O
F
L
I
P
T
O
Figure 2: Lighting Instructions.