Emulex 355 Pet Fence User Manual


 
EMULEX MODEL 355 SAN STORAGE SWITCH
USERS GUIDE APPENDIX C: EVENT MESSAGES
EMULEX CORPORATION 63
P
ART NUMBER 00041407-002 REV. B
APPENDIX C Event Messages
The event messages for the switch are listed below. For explanations, contact a customer service
representative. The message’s applicable severity level as defined below is also provided.
These severity levels can be used to designate which events trigger trap messages. Use the Command
Line Interface (CLI) to designate the minimum severity level of events to be logged in the Event Log and
at which severity level to illuminate the switch’s Fault LED.
Severity
Level
Severity Description
1 EMERG Immediate action required; system failing
2 ALERT Unrecoverable condition reported; major event in progress
3 CRIT Event failed with possible loss of integrity
4 ERR Condition failed; action required
5 WRN Failed event occurred; no action required
6 NOTIFY Configuration error or abnormal event occurred; no action required
7 INFO Event occurred; no action required
Event Event Message Severity
1 Message log cleared INFO
5 Power Supply 1 Failed ALERT
6 Power Supply 1 Online NOTIFY
9 Fan has stopped EMERG
10 Fan has returned ALERT
19 Temperatures over limit ALERT
20 Temperature OK INFO
50 SPF Overvoltage EMERG
54 SOC has detected a CRC error in the EEPROM NOTIFY
70 PORT # bypassed NOTIFY
71 PORT # inserted NOTIFY
72 Transceiver detected at port # NOTIFY
73 Transceiver removed at port # NOTIFY
74 SEOC occurred on PORT # NOTIFY
75 Port exceeded OS threshold NOTIFY
76 Port exceeded CRC threshold NOTIFY
77 Loop UP on Port # NOTIFY
78 Loop DOWN on Port # NOTIFY
79 PORT received a LIP(F8) WRN
80 PORT CRC Error detected in frame WRN
81 PORT did not receive LIPF7) within timeout WRN
82 PORT is ready to be inserted DBG
83 Segment stall on PORT # NOTIFY