USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT
EMULEX CORPORATION 37
P
ART NUMBER 00041407-002 REV. B
Adding Devices to Multiple Zones
In the previous example, each host only communicates with the devices in the same zone as the host.
However, there may be situations in which hosts in separate zones need to share devices. When this
situation occurs, use overlapping zones to share the devices between the hosts. Figure 3-15 depicts this
type of zoning configuration.
In Figure 3-15, zone 1 includes ports 1, 3, and 4, while zone 2 includes ports 2, 4 and 5. Port 4 is in both
zones. Devices on ports 1, 3, and 4 have direct access to each other and devices on ports 2, 4, and 5
have direct access to each other, but devices 1 and 3 are separated from devices 2 and 5. The device
on port 4 has direct access to all the devices on ports 1, 2, 3, and 5.
To add storage devices to multiple zones:
1. Select the appropriate zones for each port.
2. Ensure that the Zoning Active check box is selected.
3. Click Submit.
Figure 3-15: Devices in Multiple Zones
Figure 3-16: Ports in Multiple Zones on the One-Step Zoning page