PVVK-CFA FLEX VENT KIT
The flex vent kit is a flexible vent hose that is 42” in length. The flex vent kit will be used when installing a Mantis into an existing
fireplace. The flex vent kit can be cut down, but can only be cut from one end.
Cement PVC Joints
Cut End
Cement PVC Joints
Once length is determined, install two (2) 10 x 1/2” screws into the adaptor assembly to secure the adaptor assembly to the flex hose.
Using PVC cement, cement all PVC joints of the flex vent kit to the remaining PVC vent run.
FLEXIBLE
FLUE KIT
FLEXIBLE GAS
LINE
PVC PIPE SWV
(SUPPLIED BY INSTALLER)
(2) - 45 DEG. PVC BENDS
(SUPPLIED BY INSTALLER
IF NECCESSARY)
GALV. SHEET FLASHING
TO
SEAL CHIMNEY
(SUPPLIED BY INSTALLER)
VENT CAP (SUPPLIED
WITH VENT KIT)