EMI S1C Heat Pump User Manual


 
www.enviromaster.com
3
WLCA/WLHA High Wall Evaporator
CONTROLS AND COMPONENTS
Continued
PRODUCT DESCRIPTION
The AmericaSeries WLCA/WLHA is
available as a (Dx) direct expansion straight
cool and heat pump. It offers a contempo-
rary design in a ductless type evaporator and
combines attractive appearance with high
efciency conditioning for small to medium
size commercial or residential spaces. The
WLCA/WLHA is equipped with unit mounted
infrared compatible controls which also sup-
ports 24V remote wall thermostat operation.
Optional hand held remote is available.
Heat Pump models provide up to
23,000 Btuh of cooling and 20,600 Btuh of
heating. Electric heat options are available
for up to 5 kW of supplemental heat.
This American-made evaporator offers
ease of installation, operation, and service.
It can be matched with EMI’s S1CA/S1HA
09-24 and S1CA 30-36 Btuh Single-Zone
Condensing Units, the S2CA side discharge
Dual-Zone Condensing Unit, or the T2CA,
T3CA, and T4CA top discharge Multi-Zone
Condensing Units.
All EMI
Air Handlers are backed by
Enviromaster International LLC and are
tested and rated in accordance with ARI
standards 210/240 and UL 1995.
Operation modes include Heat, Cool,
Dry, Fan and Auto Change-over.
Fan Operation – Auto/On. High or Low
speed fan
Fan Purge – Fan remains on for
60 seconds after Heat/Cool call is
dropped for improved efciency (Auto
mode only)
Room air sampling: Selectable time
intervals ensure the fan will cycle
on periodically, in Auto Fan Mode
to help eliminate room temperature
stratication.
Selectable Fahrenheit (°F) or Cesius
(°C) temperature scale.
Dry mode – Operates cooling and
electric heat simultaneously to remove
humidity. Optional electric heat must
be selected.
Anti-Short Cycle Compressor Pro-
tection.
Minimum on time for heating and
cooling Helps eliminate room temper-
ature drop and system short cycling.
Freeze Protection – Prevents evapo-
rator freeze up
.
Test operation – Allows ease of test-
ing after installation (all timers are
eliminated).
Non-volatile back-up memory will
maintain control settings for an indenite
period during a power outage. When
power is restored the equipment will
resume operation after a three-minute
compressor time delay.
7-day programmable with copy feature.
Filter change indicator: A timer fea-
ture indicates when the lter should be
changed according to the selected time.
Motorized supply louver with optional
sweep or six stationary settings.
Infra red compatible control allows
use of optional IR hand held controller.
Note: Unit mounted controls are
fully functional without the handheld
remote.
CONTROLS AND COMPONENTS
Note: If the control is congured for
unit mount control do NOT connect
a wall thermostat to the unit.
Large LCD Backlit Display
Single unit mounted control pack-
age, congurable to either unit mount
or remote wall thermostat operation,
reducing model number or SKU’s
required.
Universal control can be used in
cooling only, cooling with electric heat,
heat pump, or heat pump with second
stage electric heat applications.
Operational range set point tem-
perature adjustable between 55°F and
90°F in one-degree increments.