DMP Electronics SCS-1R Home Security System User Manual


 
Digital Monitoring Products SCS-1R Installation Guide
18
opeRatoR’s GuIde
Keypad Options
KPD KPD
OPT DIAG STOP
Keypad Options (KPD OPT)
To program keypad options, press the left Select key under KPD OPT. The display
changes to CURRENT KEYPAD ADDRESS: # #.
CURRENT KEYPAD
ADDRESS: 01
Current Keypad Address
The Membrane Keypad must be set to keypad address 01. This is the default setting
and should not be changed.
KEYPAD MODE:
*SUP UNSUP
Keypad Mode
The Membrane Keypad can be set for either Supervised or Unsupervised operation. It is
recommended the setting be left at the default Supervised setting.
DEFAULT KEYPAD MSG:
Default Keypad Message
Press COMMAND to scroll past this option. The SCS-1R LCD Membrane Keypad does not
provide a programmable Keypad Message.
ARM PANIC KEYS:
PN EM F1
Arm Panic Keys
The Panic Keys should be disabled. They cannot be used on the SCS-1R LCD Membrane
Keypad. If an asterisk appears next to one of the options, for example *PN, press the
Select key under the option with the asterisk to remove the asterisk and disable the
panic key.
ACTIVATE ZONE 2
SHUNT: NO YES
Zone 2 Shunt
Leave this option set to NO.
ACTIVATE ZONE 3
EXIT: NO YES
Zone 3 Exit
Leave this option set to NO.
4 DIGIT ENTRY
CARDS: NO YES
Entry Cards
Leave this option set to NO.
ALL?: NO YES
DELAY: 2
All?
Leave this option set to NO.
Accessing Keypad Diagnostics
KPD KPD
OPT DIAG STOP
Keypad Diagnostics (KPD DIAG)
The Keypad Diagnostic option allows you to check the display segments, check the
keyboard backlighting, and test individual keys.
Press the Select key under KPD DIAG. The keypad lights all display segments and
illuminates the keyboard in green. A few seconds later the keypad turns the display off
and illuminates the keyboard in red. The keypad then alternates between these two
states for approximately two minutes. Press COMMAND at any time to continue.
PRESS KEY TO
TEST
Test Individual Keys
The display changes to PRESS KEY TO TEST. This option allows you to test each key on
the keyboard to ensure it is operating properly. Press and hold each key for about two
seconds. The key number being held appears in the display. Verify the correct number
displays before testing the next key.
Exiting the Installer Options
When done, press the COMMAND key once to return to the Installer Options screen. Press the Select key under
STOP to exit the Installer Options function.