www.desatech.com
111986-01D 31
-
(see Replacement Parts
-
If glass has been broken, carefully remove glass
door (see Removing/Replacing Glass Door, page
24). Vacuum all glass pieces with a shop vac.
CAUTION: Do not vacuum if
Use only the tempered glass door replacement
intended for this replace (see Replacement Parts,
page 36, for detail on ordering). No substitutions
may be made. See Removing/Replacing Glass Door,
page 24, for instructions for replacing glass door.
• Remove ember material before cleaning burners
and replace when cleaning is complete.
• Burner and controls should be cleaned with
compressed air to remove dust, dirt, or lint.
• Use a vacuum cleaner or small, soft bristled
brush to remove excess dust, dirt, or lint.
CLEANING AND
MAINTENANCE
Continued
LOGS
• If you remove logs for cleaning, refer to Install-
ing Logs, Lava Rock, and Glowing Embers,
page 25, to properly replace logs.
• Use a vacuum cleaner to remove any carbon
buildup on logs.
• Replace log(s) if broken. See Replacement
Parts on page 36.
• Replace ember material periodically as needed.
See Replacement Parts on page 36.
VENTING SYSTEM
Conduct annual inspection of the venting system
following these guidelines:
1. Check areas of venting system that are ex-
posed to the weather for corrosion (rust spots
or streaks and, in extreme cases, holes). Have
these items replaced immediately by a quali-
ed service person.
2. Remove the vent cap and shine a ashlight
into the vent. Remove any foreign material.
3. Check for evidence of excessive condensation.
Continuous condensation can cause corrosion
of caps, pipes, and ttings and can be caused
by having excessive lateral runs, too many
elbows, or exterior portions of the system
being exposed to cold weather.
4. Inspect joints to verify that no pipe section or
tting has been disturbed and loosened. Check
mechanical supports such as wall straps for
rigidity.