www.desatech.com
111986-01D18
FIREPLACE
INSTALLATION
Use proper gas type for replace unit you are
installing. If your gas supply is not correct, do not
install replace. See retailer where you purchased
the replace for proper replace according to your
gas type or to purchase gas conversion kit (see Ac-
cessories, page 36). A conversion kit is supplied
with the CHDV32NR.
ACCESSORIES
-
electrical outlet installed in the
Follow all instructions provided in blower ac-
cessory kit.
1. Attach the power cord to blower motor by
rmly pushing two female terminals at end
of power cord onto two spade terminals on
blower motor (see Figure 25).
2. Attach green ground wire from power cord
to blower housing using screw provided (see
Figure 25). Tighten screws securely.
3. Place blower against lower rear wall of rebox
outer wrapper with exhaust port directed up-
ward. The blower will t inside back opening
and be held in position against back wall by
magnets (see Figure 25).
4. Be certain that all wire terminals are securely
attached to terminals on blower motor and
screw retaining green ground wire is tight.
5. Mount speed control box to switch bracket by
placing plastic control shaft forward through
opening in switch bracket (see Figure 26).
6. While supporting speed control, secure control
shaft with lock nut by pushing and turning
lock nut with pliers clockwise until it is tight
against front panel. Place control knob pro-
vided on shaft.
7. Turn on power to duplex outlet if previously
turned off per the warning in column 1.
8. Plug in blower power cord.
a. If your rebox is installed as a freestanding
unit with an accessory mantel, determine
whether power cord will exit left side or
right side of rebox. Route power cord
through exit hole and plug power cord into
a wall receptacle near rebox.
b. If your rebox installation is recessed
and/or pre-wired, plug power cord into
duplex outlet provided. Refer to your
rebox owner’s manual for instructions
on wiring duplex outlet.
CAUTION: Never touch the
Figure 25 - Blower Model BK
Green
Ground Wire
Screw
Spade
Terminals
Magnetic
Strips
Exhaust
Port
Side View
Lower Firebox
Cavity
Blower
Location
Figure 26 - Attaching Speed Control to
Firebox
Switch
Bracket
Locknut
Control
Shaft
Control
Knob
Speed
Control
Blower
Plug-In
Duplex Outlet
(Located under-
neath rebox oor
against lower right
outside wall)