4. Locate four black phillips sheet metal screws
from the hardware packet.
5. Rotate hood as shown in Figure 3. Make sure
hood tabs point toward fireplace.
6. Insert hood tabs between baffle and louvers
(see Figure 3).
7. Gently rotate hood to upright position. Make
sure hood tabs are behind louvers and hood is
resting on firebox top (see Figure 3).
8. Align screw holes on hood with screw holes
on firebox top.
9. Insert screws as shown in Figure 3. Tighten
screws firmly.
ASSEMBLY
Continued
Figure 3 - Assembling Hood
Hood Tab
Sheet Metal
Screws
Louver
Baffle
Firebox Top
Hood
Hood Tabs
AIR FOR COMBUSTION
AND VENTILATION
WARNING: This fireplace
shall not be installed in a con-
fined space or unusually tight
construction unless provisions
are provided for adequate com-
bustion and ventilation air. Read
the following instructions to in-
sure proper fresh air for this and
other fuel-burning appliances in
your home.
Today’s homes are built more energy efficient than
ever. New materials, increased insulation, and new
construction methods help reduce heat loss in
homes. Home owners weather strip and caulk
around windows and doors to keep the cold air out
and the warm air in. During heating months, home
owners want their homes as airtight as possible.
While it is good to make your home energy effi-
cient, your home needs to breathe. Fresh air must
enter your home. All fuel-burning appliances need
fresh air for proper combustion and ventilation.
Exhaust fans, fireplaces, clothes dryers, and fuel
burning appliances draw air from the house to
operate. You must provide adequate fresh air for
these appliances. This will insure proper venting
of vented fuel-burning appliances.
PROVIDING ADEQUATE
VENTILATION
The following are excerpts from National Fuel
Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air
for Combustion and Ventilation.
All spaces in homes fall into one of the three fol-
lowing ventilation classifications:
1. Unusually Tight Construction
2. Unconfined Space
3. Confined Space
The information on pages 6 through 8 will help you
classify your space and provide adequate ventilation.
Unusually Tight Construction
The air that leaks around doors and windows may
provide enough fresh air for combustion and ven-
tilation. However, in buildings of unusually tight
construction, you must provide additional fresh air.