Pressure Testing Fireplace Gas
Connections
1. Open equipment shutoff valve (see Figure 24,
page 18).
2. Open main gas valve located on or near gas
meter for natural gas or open propane/LP sup-
ply tank valve.
3. Make sure control knob of fireplace is in the
OFF position.
4. Check all joints from equipment shutoff valve
to gas control valve (see Figures 25 or 26).
Apply noncorrosive leak detection fluid to all
joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Light fireplace (see Operating Fireplace,
pages 22 through 25). Check all other inter-
nal joints for leaks.
7. Turn off fireplace (see To Turn Off Gas to
Appliance, page 23).
INSTALLATION
Continued
Figure 25 - Checking Gas Joints
(Propane/LP Only)
Propane/LP
Supply Tank
Equipment Shutoff Valve
Equipment
Shutoff Valve
Gas
Meter
Figure 26 - Checking Gas Joints
(Natural Gas Only)
Gas Control Valve
Gas Control
Valve
OPTIONAL WIRELESS HAND-HELD
REMOTE CONTROL ACCESSORIES
(GHRCB Series & GHRCTB Series)
Installing Receiver
1. Remove screws.
2. Disconnect switch wires from the control valve.
3. Remove switch plate (see Figure 27). Discard
switch plate after removing. Save the screws.
4. Locate the battery clip mounted on the back
of the receiver (see Figure 28).
5. Slide 9-volt battery (not included) through
the clip.
6. Attach the terminal wires to the battery (see
Figure 28).
7. Connect wires as shown in Figure 30, page 20.
8. Install remote receiver unit onto fireplace base
using the two screws removed in step one (see
Figure 29, page 20).
Figure 27 - Switch Plate and Wiring
Harness
Figure 28 - Attaching Battery to Receiver
Receiver
Screw
Switch
Plate
Black
Wire
Red Wire
Battery Clip
9-Volt Battery
Terminal
Wires