POSSIBLE CAUSE
1. Control knob not fully
pressed in
2. Control knob not pressed in
long enough
3. Safety interlock system has
been triggered
4. Equipment shutoff valve not
fully open
5. Pilot flame not touching ther-
mocouple, which allows ther-
mocouple to cool, causing
pilot flame to go out. This
problem could be caused by
one or both of the following:
A) Low gas pressure
B) Dirty or partially clogged
ODS/pilot
6. Thermocouple connection
loose at control valve
7. Thermocouple damaged
8. Control valve damaged
1. Inlet gas pressure is too low
2. Burner orifice is clogged
3. Thermopile leads disconnected
or improperly connected
4. Burners will not come on in
remote position
1. Manifold pressure is too low
2. Burner orifice is clogged
1. Burner orifice is clogged or
damaged
2. Damaged burner
3. Gas regulator defective
4. Inlet gas pressure is too low
REMEDY
1. Press in control knob fully
2. After ODS/pilot lights, keep con-
trol knob pressed in 30 seconds
3. Wait one minute for safety in-
terlock system to reset. Repeat
ignition operation
4. Fully open equipment shutoff
valve
5. A) Contact local natural or
propane/LP gas company
B) Clean ODS/pilot (see
Cleaning and Maintenance,
pages 26 and 27) or replace
ODS/pilot assembly
6. Hand tighten until snug, then
tighten 1/4 turn more
7. Replace pilot assembly
8. Replace control valve
1. Contact local natural or pro-
pane/LP gas company
2. Clean burner (see Cleaning and
Maintenance, pages 26 and 27)
or replace burner orifice
3. Reconnect leads (see Wiring
Diagram, page 27)
4. Replace battery in hand-held
remote and receiver
1. Contact local natural or pro-
pane/LP gas company
2. Clean burner (see Cleaning and
Maintenance, pages 26 and 27)
or replace burner orifice
1. Clean burner (see Cleaning and
Maintenance, pages 26 and 27)
or replace burner orifice
2. Replace damaged burner
3. Replace gas regulator
4. Contact local natural or pro-
pane/LP gas company
OBSERVED PROBLEM
ODS/pilot lights but flame goes
out when control knob is released
Burner does not light after ODS/
pilot is lit
Delayed ignition of burner
Burner backfiring during
combustion
TROUBLESHOOTING
Continued