Louisville Tin and Stove BFT202 Fan User Manual


 
INTRODUCTION – CONT’D.
For your protection this heater is equipped with an Oxygen Depletion Sensor (ODS) pilot system. Never operate heater if
ODS has been damaged or tampered with as this could expose you to Carbon Monoxide (a colorless, odorless gas) that
could result in injury or death. Early signs of Carbon Monoxide poisoning resemble influenza, with headaches, dizziness,
or nausea. If you develop these symptoms GET FRESH AIR AT ONCE. Turn off heater and call a qualified serviceman to
check heater. Some people are more affected by Carbon Monoxide than others: Including pregnant women, persons with
a heart or lung disease, anemia, those under the influence of alcohol, and those at high altitudes.
OPERATION
The Cozy thermostatically controlled units offer the additional benefit of automatically cycling the heating to maintain just
the right room temperature. VENTFREE GAS ROOM HEATERS ARE DESIGNED STRICTLY FOR “SUPPLEMENTAL”
ROOM HEAT USE AND SHOULD NEVER BE INSTALLED AS “SOLE SOURCE HEATING”.
ROOM HEATER SPECIFICATIONS
Your room heater comes packed in a single carton. Before installation, check the rating plate to verify that the Model
Number is correct and that the room heater is equipped for the type gas you intend to use.
SAFETY INSTRUCTIONS
1) Keep burner and control compartment clean.
2) Due to high temperatures, the heater should be located out of traffic and away from furniture and draperies.
3) Children and adults should be alerted to the hazard of high surface temperature and should stay away to avoid burns
or clothing ignition.
4) Young children should be carefully supervised then they are in the same room with this heater.
5) Do not place clothing or other flammable material on or near the heater.
6) Any safety screen or guard removed for servicing must be replaced prior to operating the heater.
Page 3
MODEL NO./NAT. BFT101 BFT201 BFT301
MODEL NO./L.P. BFT102 BFT202 BFT302
Control T-Stat Bulb T-Stat Bulb T-Stat Bulb
Height 22-1/2” 22-1/2” 22-1/2”
Width 14-9/16” 20-11/16” 26-13/16”
Depth 7” 7” 7”
Max. Input BTU hr. 10,000 20,000 30,000
Min. Input BTU Hr. 6,000 10,000 20,000
Gas Supply Line Size 1/2” 1/2” 1/2”
Optional Blower No Yes Yes
Optional Floor Stand Yes Yes Yes
Bathroom Installation No No No
Bedroom Installation Yes No No
Piezo Ignitor Yes Yes Yes
Shipping Weight 22 Lbs. 32 Lbs. 35 Lbs.