Vermont Casting 20DVT Indoor Fireplace User Manual


 
10009459 23
Brookhaven Direct Vent Gas Fireplace
CO106a
DV360/580
Gas Conversion
Pilot2
1/28/00 djt
Fig. 42 Remove pilot orifice.
CO106a
Snap Ring
Index Tab
Allen
Wrench
CO105a
DV360/580
Gas Conversion
Pilot
1/28/00 djt
Fig. 41 Remove pilot hood.
CO105a
Pilot Hood
Pilot Bracket
Pilot Orifice Conversion
1. Remove pilot hood by lifting up. (Fig. 41)
2. Remove pilot orifice with 5/32” Allen wrench. (Fig.
42)
3. Install conversion pilot orifice.
4. Reinstall pilot hood and be sure to align with index
tab.
5. Turn the gas supply valve and gas valve on and test
for leaks. Use a 50/50 solution of liquid soap and
water to test for leaks at gas fittings and joints. Apply
water/soap solution with brush only - do not over ap-
ply. NEVER test with an open flame.
6. Follow procedure on rating plate to light the pilot.
Check for leaks.
7. Turn main burner on and check for leaks.
8. Reinstall logs and window frame assembly. Refer to
Page 18 for proper log placement.
Installation complete.



FP1631
Fig. 40 Back burner housing.
Air Shutter