Vermont Casting 1695 Gas Heater User Manual


 
8
Vermont Castings Intrepid Multi-Fuel
2000970
ST245
fireplace
flex connector
12/99
Flexible Con-
nector
Mantel Shield
Fireplace Adap
-
tor Kit
ST245
Fig. 7 Chimney connector enters chimney through the fire-
place opening.
Wall Pass-Throughs
Whenever possible, design your installation so that the
connector does not pass through a combustible wall. If
you are considering a wall pass-through in your instal-
lation, check with your building inspector before you
begin. Also, check with the chimney connector manu-
facturer for any specific requirements.
Accessories are available for use as wall pass-
throughs. If using one of these, make sure it has been
tested and listed for use as a wall pass-through.
Always adhere to local building codes when installing a
wall pass-through. Figure 8 shows one recommended
method.
All combustible material in the wall must be removed
around the single-wall connector to provide clearance
that is three times the pipe diameter. Any material used
to enclose the opening must be noncombustible.
Figure 9 shows an alternate method in which all com-
bustible material in the wall is cut away to provide the
required clearance that is three times the pipe diameter.
The resulting space must remain empty. A flush-mount-
ed sheet metal cover may be used on one side only. If
covers must be used on both sides, each cover must be
mounted on noncombustible spacers at least 1” (25 mm)
clear of the wall.
NOTE: Do not vent your Intrepid Multi-fuel into a fac-
tory-built (zero-clearance) fireplace. These appliances
and their chimneys are specifically designed as a unit
for use as fireplaces. It may void the listing or be haz-
ardous to adapt them for any other use.
DO NOT CONNECT AN INTREPID MULTI-FUEL TO
ANY AIR DISTRIBUTION DUCT OR SYSTEM.
ST494
steel
wall pass thru
11/00
18” (460mm) clearance all
around the pipe
Flush Mounted
Sheet Metal
Cover
ST494a
Fig. 9 An approved wall pass-through for Canada.
ST493a
Brick pass thru
11/00
I
N
T
I
P
D
R
E
I
I
Wall Stud
Chimney
Connector
Floor Protec-
tion
12” of
Noncombustible
Material
ST493a
Fig. 8 An approved wall pass-through for the United States.