Vermont Casting 1695 Gas Heater User Manual


 
16
Vermont Castings Intrepid Multi-Fuel
2000970
ST511a
Intrepid 
flue centerline
Diagrams
11/16/00
A
B
C
D
E
F
ST51
Intrepid 
flue centerline
Diagrams
11/16/00
*
A
B
C
*
D
E
F
Distance from the Center of the Flue Collar to the Wall in Top-Exit Installations
The information on this page is helpful in planning stove placement for top-exiting installations, particularly those in-
stallations with chimneys that pass through the ceiling. However, this is not a clearance chart. Final stove clearances
must adhere to the guidelines stated in the clearance charts on Page 13.
** To locate center of flue collar for corner installation, add 7” (178 mm) to the clearance distance from stove corner to wall. Mark off the resulting
distance from the corner along both walls. Next, measure the same distance from these two points out from the walls. These last two measure
-
ments will meet at a point representing the center of the flue collar. Refer to the diagrams above.
Side (A) Rear (B) Corner (C) Side (D) Rear (E) Corner (F)
34³⁄₄ 15” 18³⁄₄ 22³⁄₄ 8” 16³⁄₄
(883 mm) (381 mm) (476 mm) (578 mm) (203 mm) (426 mm)
Parallel Installations
Corner
Installations**
Corner
Installations**
Parallel Installations
Intrepid Mult-fuel: WITH Stove and Chimney Connector Heat Shields
Unprotected Surfaces Protected Surfaces
ST511a
Side (A) Rear (B) Corner (C) Side (D) Rear (E) Corner (F)
34³⁄₄ 29” 26³⁄₄ 22³⁄₄ 11” 16³⁄₄
(883 mm) (737 mm) (680 mm) (578 mm) (279 mm) (426 mm)
Parallel Installations
Corner
Installations**
Corner
Installations**
Parallel Installations
Intrepid Multi-fuel: WITHOUT Stove and Chimney Connector Heat Shields
Unprotected Surfaces Protected Surfaces
ST511
* This distance, from the center of the flue collar to the front edge of the hearth, is the same for all installations on this page: 35” in the United
States and 37” (940mm) in Canada.