Burnham IN3 Boiler User Manual


 
39
L. Water Boiler with Continuous Ignition (Standing Pilot)
and Intermittent Circulation. See Figure 39.
1. Normal Operation
a. Thermostat calls for heat.
b. Vent Damper (if used) opens as stated in Vent
Damper Sequence of Operation.
c. Gas Valve(s) is energized allowing main gas ow
and ignition of Main Burners.
d. After Thermostat is satised Gas Valve(s) is de-
energized, extinguishing main ame. Vent
Damper (if used) closes.
2.
Safety Shutdown
a. Limit: Automatically interrupts main burner
operation when water temperature exceeds set
point. Maximum allowable temperature is 250°F.
Normal operation resumes when water
temperature falls below set point.
b. Blocked Vent Switch. Automatically interrupts
main burner operation when excessive vent
system blockage occurs. Control is a multiple
use device. If blocked vent switch is activated do
not attempt to place boiler in operation. Correct
source of blockage and reset blocked vent
switch.
c. Flame Roll-out Switch. Automatically interrupts
boiler operation when ames or excessive heat
are present in vestibule. Control is single use
device. If ame roll-out switch is activated do
not attempt to place boiler in operation. Correct
source of blockage and replace ame roll-out
switch.
d. Thermocouple: senses pilot ame and causes gas
valve to turn off main burner and pilot burner gas
ow should pilot burner ame extinguish.