Bryant SYSTXBBUIZ01 Thermostat User Manual


 
NOTE: Range of outdoor unit Btu selection is limited by model
number of indoor unit installed. The Evolution Zone Control
will not allow an outdoor unit size that is not supported by the
installed indoor unit.
NOTE: On new system installations, the model and serial number
will be recognized and displayed. On any indoor/outdoor board
replacements, the equipment will be recognized but the exact
model/serial number will not be displayed.
C. Section 3 Selecting Electric Heater
If indoor unit is a fan coil and the electric heater is not
self-identifying, ELECTRIC HEATER NOT IDENTIFIED will
appear (See Fig. 17). Press either Time or Temp +/- buttons to
select appropriate size of electric heater installed, then press
right-side button to continue.
NOTE: Range of electric heaters available is limited by model
number of the fan coil installed. The Evolution Zone Control
will not allow an electric heater size that is not supported by the
installed fan coil.
D. Section 4 Selecting Accessories
Once the indoor and outdoor equipment have been found or
entered, the following screens will appear allowing the Installer to
select the AIR FILTER TYPE; HUMIDIFIER INSTALLED; and
UV LIGHTS INSTALLED (See Fig. 18). Use either Time or
Temp +/- buttons to make appropriate selections in the highlighted
area on the display screen. Press right-side button to continue (or
advance) to the next screen.
AIR FILTER TYPE This accessory screen will appear first.
The installer will need to enter the type of filter (MEDIA, EAC, or
both). See Table 1 and make a selection using Time or Temp +/-
button, then press right-side button to continue.
HUMIDIFIER INSTALLED This will appear after the Air
Filter Type screen. Select whether a humidifier is installed on the
system, YES or NO, then press right-side button to continue.
UV LIGHTS INSTALLED This screen will appear to select
whether UV lights are installed on the system, select YES or NO,
then press right-side button to continue.
E. Section 5 Zoning
SEARCHING FOR ZONE EQUIPMENT will appear on the
screen to identify the number of zones detected. This screen will
show Zone 1, Zone 2, etc. and indicate all zones having either a
remote room sensor, or smart sensors associated with them. If the
system contains smart sensors, they must be assigned a zone
number before continuing. See Smart Sensor Installation Instruc-
tions on how to assign Smart Sensors to their respective zones.
When finished, press right-side button to continue. See Fig. 18a.
F. Section 6 Equipment Summary
The EQUIPMENT SUMMARY screen will appear after Ac-
cessories and Zoning have been selected. This screen will give a
summary of all equipment automatically found or manually
selected. If a wrong selection was made, press left-side button
(BACK selection) to go back to that particular screen and make
changes. When everything is OK, press right-side button again to
continue. (See Fig. 19)
The SETUP COMPLETE! SAVE ALL SELECTIONS?
screen will appear after Equipment Summary. To Save All
Selections press (YES) right-side button. Pressing the left-side
button (NO selection) will return to the Equipment Summary
screen where changes can be performed to any of the equipment
selection screens. After selecting YES, the initial power up
sequence of the new Evolution Zone Control is complete. The
User Interface screen will now display normal operating mode.
G. Section 7 Duct Assessment
The following screen will appear after Setup is exited. Press
right-side button to start Duct Assessment. Duct Assessment will
measure the relative size of the ductwork, including damper
leakage. These measurements are used to control the correct
amount of airflow in the zoned system. Status messages will
appear on the screen to indicate what the system is doing. The
process will take approximately one minute per zone. At the end of
the process, the display will show the relative size of each zone
duct. See Fig. 19a.
Fig. 17Selecting Electric Heater
A03197
ELECTRIC HEATER
NOT IDENTIFIED
ENTER SIZE: 5 KW
NONE, 5,10,15 KW
PRESS +/- TO MAKE
SELECTION
BACK CONTINUE
INSTALLED FILTER MENU SELECTION
1 Inch to 4 inch media MEDIA
High voltage EAC EAC
High voltage EAC+1to4inch media MEDIA + EAC
Table 1 Filter Selection
Fig. 18Accessories UV Lights
A03198
ACCESSORIES
HUMIDIFIER
INSTALLED? YES
PRESS +/- TO MAKE
SELECTION
BACK CONTINUE
ACCESSORIES
U.V. LIGHTS
INSTALLED? YES
PRESS +/- TO MAKE
SELECTION
BACK CONTINUE
ACCESSORIES
AIR FILTER TYPE:
EAC EAC
MEDIA
MEDIA + EAC
PRESS +/- TO MAKE
SELECTION
CONTINUE
AIR FILTER MEDIA TYPE HUMIDIFIER INSTALLED? U.V. LIGHTS INSTALLED?
ZONING
SEARCHING FOR
ZONE EQUIPMENT
WORKING
ZONING
ZONE 1 UI
ZONE 2 RS
ZONE 3 RS
ZONE 4 RS
UI=USER INTERFACE
RS=REMOTE SENSOR
SS=SMART SENSOR
BACK CONTINUE
Fig. 18a Zoning
A04084
Fig. 19Equipment Summary
A04109
EQUIPMENT SUMMARY
FURNACE 355MAV0420
AC 598BNX024
FILTER EAC
HUMIDIFIER YES
UV LIGHTS YES
ZONES 12345678
NO YES
SETUP
COMPLETE!
SAVE
ALL SELECTIONS/
NO YES
DUCT ASSESSMENT
MEASURE DUCT
CAPACITY FOR EACH
ZONE.
4 MINUTES ARE REQUIRED
TO COMPLETE
PRESS START TO BEGIN
QUIT START
DUCT ASSESSMENT
ASSESSMENT ACTIVE
PLEASE WAIT
OPENING ALL ZONES
AIRFLOW STABILIZING
PROGRESS
STOP
DUCT ASSESSMENT
ZONE CAPACITY
ZONE1 25
ZONE 2 20
ZONE 3 25
ZONE 4 20
DAMPER LEAKAGE 10
QUIT START
Fig. 19a Duct Assessment
A04085
6