Bryant SYSTXBBUIZ01 Thermostat User Manual


 
NOTE: Read the entire instruction manual before starting the
installation.
This symbol indicates a change since the last issue.
TABLE OF CONTENTS
SAFETY CONSIDERATIONS.....................................................1
INTRODUCTION..........................................................................1
INSTALLATION AND START-UP OVERVIEW......................1
INSTALLATION...........................................................................1
INITIAL POWER-UP....................................................................5
QUICK START..............................................................................7
INSTALL / SERVICE MENUS....................................................7
OPERATIONAL INFORMATION.............................................12
TROUBLESHOOTING ...............................................................13
SAFETY CONSIDERATIONS
Read and follow manufacturer instructions carefully. Follow all
local electrical codes during installation. All wiring must conform
to local and national electrical codes. Improper wiring or installa-
tion may damage the Evolution™ Zone System. Recognize safety
information. This is the safety-alert symbol
. When you see this
symbol on the equipment and in the instruction manual, be alert to
the potential for personal injury. Understand the signal words
DANGER, WARNING, and CAUTION. These words are used
with the safety-alert symbol. DANGER identifies the most serious
hazards, which will result in severe personal injury or death.
WARNING signifies a hazard, which could result in personal
injury or death. CAUTION is used to identify unsafe practices,
which may result in minor personal injury or product and property
damage. NOTE is used to highlight suggestions which may result
in enhanced installation, reliability, or operation.
INTRODUCTION
The Evolution Zone System consists of several intelligent com-
municating components which includes the Evolution Zone Con-
trol (or User Interface), Smart Sensors, Damper Control Module,
variable- speed furnace or FE fan coil, 2-speed AC or HP, which
continually communicate with each other via a four-wire connec-
tion called the ABCD bus. Commands, operating conditions, and
other data are passed continually between components over the
ABCD bus. The result is a new level of comfort, versatility, and
simplicity.
All furnaces or fan coils are variable-speed and multi stage for
maximum flexibility, efficiency, and comfort. They support con-
trolled ventilation, humidification, dehumidification, and air qual-
ity control. Either a dual capacity (communicating), or a standard
24 vac controlled outdoor unit may be used.
When using conventional outdoor units, the variable-speed furnace
or fan coil provides the 24 volt signals needed to control them.
Also, the Evolution™ Damper Control Module (P/N
SYSTXBB4ZC01) allows connection of a conventional HRV or
ERV without the need for a separate wall control.
All system components are controlled through the wall mounted
Evolution™ Zone Control, which replaces the conventional ther-
mostat and provides the homeowner with a single wall control for
all features of the system.
INSTALLATION AND START-UP OVERVIEW
This instruction covers installation of the Evolution™ Zone
Control only. Physical installation instructions for the indoor and
outdoor equipment, Damper Control Module, and accessories are
provided with each unit.
Setup, commissioning, operation, and troubleshooting of the
Evolution Zone System is covered only in this installation instruc-
tion. It is the guide to connecting the system components and
commissioning the system once all physical components are
installed. Special screen prompts and start-up capabilities are
provided in the Evolution System to simplify and automate the
initial commissioning of the system.
Install Evolution™ Zone Control according to this instruction.
Install indoor unit, outdoor unit, and accessories according to
their instructions.
Wire complete system according to this instruction.
Setup, commission, and operate system according to this
instruction to assure a smooth and trouble free start-up.
INSTALLATION
A. Step 1 Check Equipment and Job Site
INSPECT EQUIPMENT File claim with shipping company,
prior to installation, if shipment is damaged or incomplete.
HOLD
COOL
HEAT
OFF
EVOLUTION
SYSTEM
ZONE
Evolution™ Zone Control
SYSTXBBUIZ01
A04031
Installation and Start-Up Instructions
Evolution™ Zone Control
SYSTXBBUIZ01
Cancels: New II UIZ01-0-1
03-04
—1—