Bryant 698B Heat Pump User Manual


 
XIV. FINAL CHECKS
IMPORTANT: Before leaving job, be sure to do the following:
1. Ensure that all wiring and tubing is secure in unit before
adding panels and covers. Securely fasten all panels and
covers.
2. Tighten service valve stem caps to 1/12-turn past finger
tight.
3. Leave Users Manual with owner. Explain system operation
and periodic maintenance requirements outlined in manual.
4. Fill out Dealer Installation Checklist and place in customer
file.
CARE AND MAINTENANCE
For continuing high performance and to minimize possible equip-
ment failure, periodic maintenance must be performed on this
equipment. Frequency of maintenance may vary depending upon
geographic areas, such as coastal applications.
TABLE 7TWO-SPEED COMPRESSOR
(WINDING RESISTANCE AT 70°F±20°)
WINDING 2 TON 3 TON 4 TON 5 TON
Start (S-C) 2.280 1.850 1.459 0.740
Run (R-C) 0.770 0.745 0.552 0.356