Brother BE-1204B-BC Sewing Machine User Manual


 
9-6 BE-1204B-BC • BE-1206B-BC
Chapter 9 Error code list
Code Error Messages Error Measures
E-BD
Lower shaft flash
memory error
Lower shaft flash memory error
E-BE
Lower shaft version-up
error
Lower shaft version-up error
E-BB,
BF
ERROR BB, BF Lower shaft motor undefined error
E-C1 ERROR C1 Area over during embroidering
This is not displayed in this model.
E-C2 Wiper out error Wiper out error
If the wiper is tangled with a thread, remove it.
Press the
or turn on the F/B switch on the
head to either side.
E-C3 ERROR C3 Embroidering data buffer empty
Check the connection of the communication
cable of the panel. If the cable is connected
correctly , press the
or turn on the F/B
switch on the head to either side. If the cable is
disconnected , turn off the power and connect the
cable.
E-C4 Presser foot down error Presser foot down error
E-C5 ERROR C5
Measured voltage value could not
be received form the lower shaft
motor CPU.
E-C6 ERROR C6
Voltage value could not be
transferred to the lower shaft motor
CPU.
E-C7 ERROR C7 Lower shaft error
E-C8 ERROR C8 Hook motor origin point error
E-C9 Embroidering start error Embroidering start error
E-CA ERROR CA No sewing permisson
This is not usually displayed.
E-CB
Spindle rotation speed
error
Spindle rotation speed error
Press the
or turn on the F/B switch on the
head to either side to cancel the error and press
the
. If the same error occurs again, there
is a possibility that the spindle is overloaded.
E-CC ERROR CC
Shuttle thread entanglement
automatic reset
This is not usually displayed.
E-CD
Spindle rotation
command sending error
Speed command can not be
received.
Turn the power off and on once. If the same
error occurs again, the main PCB is faulty.
E-CE
Cylinder bed position
error
Cylinder bed position error
E-CF ERROR CF
Rated voltage value could not be
received from the lower shaft
motor CPU.
This is not usually displayed.
E-D0 Power PC board error Power PC board error
Turn the power off and on once. If the same
error occurs again, the power PCB is faulty.
E-D1 Cooling fan motor stop Cooling fan motor stop. This is not usually displayed.
E-D2
Power voltage upper
limit error
Power voltage upper limit error
E-D3
Power voltage lower
limit error
Power voltage lower limit error
(1) The voltage setting is improper. -> Set it
again.
(2) Press the
or turn on the F/B switch on
the head to either side. If the same error
occurs again, the power PCB or the power
supply is faulty.
E-D4
Thread trimming motor
overcurrent
Thread trimming motor overcurrent
Turn OFF the power. The possible causes for this
error are, troubles of the thread trimming motor,
troubles of the main PCB, and troubles of the
drive PCB.