Bradford-White Corp IGI-180C-5(N Water Heater User Manual


 
II - SPECIFICATIONS - GENERAL
Safety devices Appliance - AC 120 Volts - 60Hz. 15A - Dedicated
Remote control DC 12 Volts (Digital)
Flame failure - Flame rod
Boiling protection - 203°F
Remaining flame (OHS) 194°F bi-metal switch
Thermal fuse 264°F
Automatic frost protection - Bimetal sensor & anti-frost heaters
Combustion fan rpm check - Integrated circuit
Over current - Glass fuse (3 amp)
If remote fails or becomes disconnected unit defaults to
100°F with water flowing, this is an anti-scald feature.
Remote control cable Non-polarized two core cable or low voltage thermostat wire
Clearances from combustibles Top of heater 6" (12" min. recomended for service)
Front of heater 6" (24" min. recomended for service)
Sides of heater 2"
Back of heater 0"
Floor 12"
Vent/Air Intake 0"