Bosch Appliances ICP-CC488 Home Security System User Manual


 
ICP-CC488 | Installation Guide | 14.0 Zone Information EN | 60
Bosch Security Systems, Inc. | 12/08 | F01U089457-02
14.3.2 Zone Types
The zone types are listed in Table 48.
Table 48: Zone Types
Zone Type Description
0 Instant
1 Handover
2 Delay-1
3 Delay-2
4 Reserved
5 Reserved
6 24-Hour Medical
7 24-Hour Panic
8 24-Hour Holdup
9 24-Hour Tamper
10 Reserved
11 Keyswitch
12 24-Hour Burglary
13 24-Hour Fire
14 Chime Only
15 Not used
0 – Instant Zone
An Instant Zone (Contact ID Event Code 130)
immediately sounds the sirens and operates the dialer
if it is unsealed after the Exit Timer expires.
If an Instant Zone is not restored when the time the
system is disarmed, a Zone Restore Report is
automatically sent to the receiving party.
1 – Handover Zone
A Handover Zone (Contact ID Event Code 130) acts
as an Instant Zone if it is activated by itself. If a
Handover Zone is activated after a Delay Zone, the
remaining Delay Time is handed over from the
Delay Zone to the Handover Zone.
Handover can be sequential or non-sequential. The
default settings is sequential handover. You can
disable sequential handover by disabling Option 8 in
Location 494 (refer to Section 18.3 System Options 3 on
page 81).
If a Handover Zone is not restored when the system
is disarmed, a Zone Restore Report is automatically
sent to the receiving party.
2 – Delay-1 Zone
A Delay-1 Zone (Contact ID Event Code 130) has a
delay time determined by the value in Locations 466
and 467 (refer to Section 17.2 Entry Timer 1 on page
78). After Entry Time expires, the system activates an
alarm.
If a Delay-1 Zone is not restored when the system is
disarmed, a Zone Restore Report is automatically
sent to the receiving party.
3 – Delay-2 Zone
A Delay-2 Zone (Contact ID Event Code 130) has a
delay time determined by the value in Locations 468
and 469 (refer to Section 17.3 Entry Timer 2 on page
78). After Entry Time expires, the system activates an
alarm.
If a Delay-2 Zone is not restored when the system is
disarmed, a Zone Restore Report is automatically
sent to the receiving party.
6 – 24-Hour Medical Zone
A 24-Hour Medical Zone (Contact ID Event Code
100) is always ready to activate the dialer, horn
speaker, bell, and strobe, whether the system is
armed or disarmed. A Medical Report is transmitted
to the base station receiver. A 24-Hour Medical Zone
does not send a Restore Report until the zone is
restored.
7 – 24-Hour Panic Zone
A 24-Hour Panic Zone (Contact ID Event Code 120)
is always ready to activate the dialer, horn speaker,
bell, and strobe, whether the system is armed or
disarmed. A Panic Report is transmitted to the base
station receiver. A 24-Hour Panic Zone does not
send a Restore Report until the zone is restored.
8 – 24-Hour Holdup Zone
A 24-Hour Holdup Zone (Contact ID Event Code
122) is always ready to activate the dialer, horn
speaker, bell, and strobe, whether the system is
armed or disarmed. If you want the holdup alarm to
be silent, select Option 4 in the first Zone Options
location (refer to Section 14.3.5 Zone Options 1 on page
61). A 24-Hour Holdup Zone does not send a
Restore Report until the zone is restored.
9 – 24-Hour Tamper Zone
A 24-Hour Tamper Zone (Contact ID Event Code
137) is always ready to activate the dialer, horn
speaker, bell, and strobe, whether the system is
armed or disarmed. A 24-Hour Tamper zone does
not send a Restore Report until the zone is restored.
11 – Keyswitch Zone
Use a Keyswitch Zone to connect a keyswitch to
operate the system. Refer to Section 14.3.6 Keyswitch
Zone Options for information on programming this
zone type. User Code 16 is reported when arming
and disarming using this method of operation.
Programming the priority level of User Code 16 also
affects the operation of the Keyswitch Zone. Refer to
Section 13.3 User Code Priority for more information.
12 – 24-Hour Burglary Zone
A 24-Hour Burglary Zone (Contact ID Event Code
133) is always ready to activate the dialer, horn
speaker, bell, and strobe, whether the system is
armed or disarmed. A 24-Hour Burglary zone does
not send a Restore Report until the zone is restored.