Bosch Appliances ICP-CC488 Home Security System User Manual


 
ICP-CC488 | Installation Guide | 25.0 Programming Sheets EN | 104
Bosch Security Systems, Inc. | 12/08 | F01U089457-02
Zones
Location
267 to 378 Refer to page 58
Zone 1
Locations 267 to 273
Default
2 0 0 1 14 1 1
Zone 2
Locations 274 to 280
Default
1 0 0 1 14 1 1
Zone 3
Locations 281 to 287
Default
1 0 0 1 14 1 1
Zone 4
Locations 288 to 294
Default
1 0 0 1 14 1 1
Zone 5
Locations 295 to 301
Default
0 0 0 1 14 1 1
Zone 6
Locations 302 to 308
Default
0 0 0 1 14 1 1
Zone 7
Locations 309 to 315
Default
0 0 0 1 12 1 1
Zone 8
Locations 316 to 322
Default
9 0 0 1 12 1 1
Zone 9
Locations 323 to 329
Default
15 0 0 1 14 1 1
Zone 10
Locations 330 to 336
Default
15 0 0 1 14 1 1
Zone 11
Locations 337 to 343
Default
15 0 0 1 14 1 1
Zone 12
Locations 344 to 350
Default
15 0 0 1 14 1 1
Zone 13
Locations 351 to 357
Default
15 0 0 1 14 1 1
Zone 14
Locations 358 to 364
Default
15 0 0 1 14 1 1
Zone 15
Locations 365 to 371
Default
15 0 0 1 14 1 1
Zone 16
Locations 372 to 378
Default
15 0 0 1 14 1 1
Each zone contains seven locations. The first three
locations determine how the zone operates:
Zone Type Zone Pulse
Count
Zone Pulse
Count Time
The next two locations contain zone options:
Zone Options 1 Zone Options 2
The last two locations contain reporting information:
Report Code Dialer Options
Zone Types
These are the zone types available:
Zone Type Description
0 Instant
1 Handover
2 Delay-1
3 Delay-2
4 Reserved
5 Reserved
6 24-Hour Medical
7 24-Hour Panic
8 24-Hour Holdup
9 24-Hour Tamper
10 Reserved
11 Keyswitch
12 24-Hour Burglary
13 24-Hour Fire
14 Chime only
15 Zone not used
Zone Pulse Count Settings
Program the pulse count settings for each zone from
0 to 15.
Zone Pulse Count Time
Zone pulse count time is the time frame or period
over which the number of pulses must register.
20 ms Loop Response 150 ms Loop Response
Option Time (sec) Option Time (sec)
0 0.5 8 20
1 1 9 30
2 2 10 40
3 3 11 50
4 4 12 60
5 5 13 90
6 10 14 120
7 15 15 200
Zone Options 1
Option Description
1 Lockout siren/lockout dialer
2 Delay alarm reporting
4 Silent alarm
8 Sensor watch
Zone Options 2
Option Description
1 Isolated in STAY Mode 1
2 Zone isolation allowed
4 Forced arming allowed
8 Enable Zone Restore Report