Bosch Appliances ICP-CC488 Home Security System User Manual


 
ICP-CC488 | Installation Guide | 25.0 Programming Sheets EN | 106
Bosch Security Systems, Inc. | 12/08 | F01U089457-02
Codepad Panic Report
Location
405 to 406 Refer to page 67
Default
7 15
Codepad Fire Report
Location
407 to 408 Refer to page 68
Default
7 14
Codepad Medical Report
Location
409 to 410 Refer to page 68
Default
7 13
Codepad Reporting Options
Location
411 Refer to page 68
0 No report required
1 Receiver 1
2 Receiver 2
4 Receiver 1 and 2
8 Receiver 2 only when Receiver 1 fails
System Status – AUX Power Supply Fail Report
Location
412 to 413 Refer to page 68
Default
10 3
System Status – AUX Power Supply Fail Restore
Report
Location
414 to 415 Refer to page 68
Default
10 8
System Status – AC Fail Report
Location
416 to 417 Refer to page 68
Default
10 2
System Status – AC Fail Restore Report
Location
418 to 419 Refer to page 68
Default
10 7
System Status – Low Battery Report
Location
420 to 421 Refer to page 69
Default
10 1
System Status – Low Battery Restore Report
Location
422 to 423 Refer to page 69
Default
10 6
System Status – Access Denied
Location
424 to 426 Refer to page 69
Default
6 7 12
Location 424 Code retries
Location 425 Reporting code – tens digit
Location 426 Reporting code – units digit
System Status Reporting Options
Location
427 Refer to page 69
0 No report required
1 Receiver 1
2 Receiver 2
4 Receiver 1 and 2
8 Receiver 2 only when Receiver 1 fails
Test Reporting Time
Location
428 to 434 Refer to page 69
Default
0 0 0 0 7 1 0
Location 428 Hour of the day – tens digit
Location 429 Hour of the day – units digit
Location 430 Minute of the day – tens digit
Location 431 Minute of the day – units digit
Location 432 Test Report code – tens digit
Location 433 Test Report code – units digit
Location 434 Repeat interval in days
Test Reporting Dialer Options
Location
435 Refer to page 70
0 No report required
1 Receiver 1
2 Receiver 2
4 Receiver 1 and 2
8 Receiver 2 only when Receiver 1 fails
Output Configurations
Location
436 to 465 Refer to page 70
Output 1
Locations 436 to 441
Default for horn speaker
1 14 0 0 0 0
Output 2
Locations 442 to 447
Default for Fire Alarm
verification
2 7 10 2 1 5
Strobe
Locations 444 to 453
Default for strobe (reset in 8 hr)
2 0 6 4 0 8
Relay
Locations 454 to 459
Default for sirens running
1 15 1 0 0 0
Codepad
Locations 460 to 465
Default for entry/Exit Warning
and Delay Alarm
0 13 2 1 0 1
Outputs are programmed with four parameters in six
locations:
Event Type Polarity Time Base Time Multiplier
Entry Time 1
Location
466 to 467 Refer to page 78
Default
4 1
Location 466 Increments of 1 sec (0 to 15 sec)
Location 467 Increments of 16 sec (0 to 240 sec)
Entry Time 2
Location
468 to 469 Refer to page 78
Default
8 2
Location 468 Increments of 1 sec (0 to 15 sec)
Location 469 Increments of 16 sec (0 to 240 sec)
Exit Time
Location
470 to 471 Refer to page 78
Default
12 3
Location 470 Increments of 1 sec (0 to 15 sec)
Location 471 Increments of 16 sec (0 to 240 sec)