Bissell 9400 Vacuum Cleaner User Manual


 
19
www.bissell.com
Troubleshooting
Built-in heater ready light does not illuminate
Possible Cause Remedies
1. The heater switch is not turned ON ( I ). 1. Turn the heater switch ON ( I ).
2. The power switch is not turned ON ( I ). 2. Both switches must be ON ( I ) to
activate the heater ready light.
Reduced spray or no spray.
Possible Cause Remedies
1. 2-in-1 water tank may be empty. 1. Fill heavy duty bladder with hand hot
tap water.
2. Formula tank may be empty. 2. Fill formula tank with BISSELL Deep
Cleaning Formula for cleaning.
3. 2-in-1 water tank may not be 3. Turn power switch OFF ( O ).
seated completely. remove and reseat 2-in-1 water tank.
4. Pump may have lost prime. 4. Turn power switch OFF ( O ) and
then back ON ( I ). Wait one minute,
then depress spray trigger.
DirtLifter PowerBrushes do not turn
Possible Cause Remedies
1. The brush is off or broken. 1. Turn power switch OFF ( O ) and
unplug unit from outlet. Follow
instructions on page 17.
2. The unit is in the upright position. 2. Brushes only rotate when unit is
reclined using the detent pedal
.
3.
Circuit breaker may have tripped.
3. Turn the power switch OFF ( O ) and
unplug from outlet. Check to see if
foreign object is caught in brush roll.
remove object. Plug machine back in
to reset circuit breaker
.
Scotchgard protector applicator tool is not spraying
Possible Cause Remedies
1. Cartridge is not connected to the tool. 1. Follow instructions on cartridge to
assure proper fit.
2. Ready Tools dial on floor setting. 2. Set Ready Tools dial to hose
attachments setting
.
3.
Formula clogging the spray trigger.
3. Soak applicator tool only in hand hot
water. Spray without the cartridge
attached to purge any residual
formula left in the applicator tool
.
WARNING:
To reduce the risk of fire,
electric shock or injury
unplug from the outlet
before servicing.
ug310-5880_9200E_406.indd 19ug310-5880_9200E_406.indd 19 6/9/06 4:25:46 PM6/9/06 4:25:46 PM