Avalon Stoves Flush Wood Insert Indoor Fireplace User Manual


 
Installation (for qualified installers only) 9
© Travis Industries 100-01157 4041116
Insert Placement Requirements
The insert must be placed so that no combustibles are within, or can swing within (e.g. drapes,
doors), 36" of the front of the insert
Insert and hearth must be installed on a level, secure floor
The minimum clearances, facing, and hearth requirements in Figure 3 must be met.
Side
Wall
Combustible Mantel
Combustible Top Facing
Non-Combustible
Hearth
Facing
Minimum Clearances
k
l
m
n
o
p
q
x
Sidewall to Insert
Side Facing
Top Facing*
Mantel to Insert*
Hearth (Front)
Hearth (Side)
Front of Insert
Extension onto Hearth
9"
9"
39"
41-1/2"
16"
8"
36"
1-1/4"
q
l
k
p
x
o
n
m
* Measure from the base of the
fireplace insert.
Figure 3
Face Dimensions
33”
23-1/4”
33-1/2”
23-1/4”
33-3/8”
51-1/2”
Radius
23-7/8”
2-7/8”
Avalon Victorian Lace
Fireplace Xtrordinair Arched
Lopi Wilmington
Figure 4