Avalon Stoves Flush Wood Insert Indoor Fireplace User Manual


 
10 Installation (for qualified installers only)
© Travis Industries 100-01157 4041116
Drafting Performance
This appliance relies upon natural draft to operate. External forces, such as wind, barometric pressure,
topography, or factors of the home (negative pressure from exhaust fans, chimneys, air infiltration, etc.),
may adversely affect draft. Travis Industries can not be responsible for external forces leading to less
than optimal performance.
Leveling Bolt Installation
Two leveling bolts are included to level the insert if the fireplace has a stepped-up hearth. To install, raise
the rear of the insert up and insert the leveling bolts into the holes in the rear corners of the insert. Adjust
the bolts until they extend the same height as the hearth steps up. After the insert is installed, fine-tune
the leveling bolts to level the insert (see Figure 5).
The leveling bolts
should stick out
this far from the
base of the insert.
Fireplace
Hearth
The leveling bolts
go into the holes
at the rear corners
of the insert.
Figure 5
Flue Installation
Included in the owners pack are
three flue brackets and six self-
drilling screws. Use these
components to secure the flue to the
fireplace insert.
Flue Opening
Flue (flexible or rigid)
Flue Bracket
Self-Drilling Screws
Figure 6