Avalon Stoves Flush Wood Insert Indoor Fireplace User Manual


 
6 Features & Specifications
© Travis Industries 100-01157 4041116
Installation Options:
Masonry Fireplace Insert
WARNING: Do not install this fireplace insert into a
factory-built metal (Z.C.) fireplace.
Features:
EPA Phase II Approved
2.9 Cubic Foot Firebox Volume
Single Operating Control
Accepts Logs Up to 24" Long
Steel Plate Construction (5/16" & 1/4")
Heavy Duty Refractory Firebrick
Standard High-Tech Blower
Five Sided Convection Chamber
Heating Specifications:
Approximate Maximum Heating Capacity (in square feet)* 1,200 to 2,000
Maximum BTU's per Hour (Cord Wood Calculation) 73,300
Overall Efficiency (Oregon Method) 71.1 %
Maximum Burn Time Up to 12 Hours
* Heating capacity will vary depending on the home's floor plan, degree of insulation, and the outside
temperature. It is also affected by the quality and moisture level of the fuel.
Dimensions:
5-5/8"
Weight 450 Lbs.
Fireplace Opening
21-1/4"
11-1/8"
1-1/4”
NOTE:
Clearances are
measured from the base
of the fireplace insert.
6" Diameter Flue Vent
20-1/2"
21-1/2"
28-7/8"
Electrical Line
(may be re-routed
to opposite side)
Figure 1
Emissions:
4.1 Grams Per Hour (EPA Phase II Approved)