American Water Heater ITCE3-52/80/119 Water Heater User Manual


 
Servicing should only be performed by a Qualified Service Agent
63
RESTORE FACTORY DEFAULTS MENU
This control system menu allows the user to restore most of the control system’s user
settings to their factory default settings. User settings in the Alarm Output Setup and
Display Settings menus are unaffected by executing Restore Factory Defaults.
Restore Factory Defaults
Factory Default User Settings
ACTION DISPLAY
From the Main Menu use the Up/Down buttons to select
(highlight in black) the “Restore Factory Defaults” menu.
Press the Operational Button underneath “SELECT.”
The Restore Factory Defaults menu will be displayed.
From the Restore Factory Defaults menu press the
Operational Button underneath “YES.” The display will
show text confirming the factory default settings have
been restored.
Press the Operational Button underneath “BACK” to exit
the Restore Factory Defaults menu.
TEMPERATURES MENU DEFAULT SETTING ADJUSTABLE RANGE
Operating Set Point 120°F (49°C) 90ºF to 190ºF (32°C to 88°C)
Differential Settings 2°F (1°C) 1°F to 20°F (1°C to 11°C)
Tank Probe Offset 0°F (0°C) -5°F to +5°F (-3°C to +3°C)
ECONOMY MODE SETUP MENU DEFAULT SETTING ADJUSTABLE RANGE
Setpoint Adjustment 20°F (11°C) 2°F to 50°F (1°C to 28°C)
Daily Operating Mode Normal Operation All Day See page 55
ALARM OUTPUT SETUP MENU DEFAULT SETTING ADJUSTABLE RANGE
Alarm Output Function Disabled See page 59
Alarm SP 100 (38°C) 90ºF to 190ºF (32°C to 88°C)
DISPLAY SETTINGS MENU DEFAULT SETTING ADJUSTABLE RANGE
Temperature Units °Fahrenheit °Fahrenheit or °Celsius
Backlight Delay 10 Seconds Always off/on, 10, 30, 60 Sec
Contrast 30% 20% to 100%