The next four items allow you to change each digit of your security code. The Set switch is
used to increment the value of each digit. The Mode/Advance switch is used to enter each digit
and advance to the next.
Next, the programmed characteristics of each transmitter is displayed. The transmitter number
is shown in the LED Display. If no transmitter is programmed for an address, neither the Mode
LED nor the Type LED will be lit. If a transmitter is programmed, the Mode LED indicates
whether the transmitter sends restore transmissions and the Type LED shows whether the
transmitter is supervised.
The Mode LED is on if the transmitter sends restore transmissions, and off if it doesn't.
The Type LED is on steady if the transmitter is supervised, and blinks if it isn't.
The Set switch is used to change the characteristics of a programmed transmitter. Each press of
the Set switch cycles through each combination of supervised, sends restores, or no transmitter
programmed.
The Mode/Advance switch is used to change to the next transmitter address. Set Up mode is
exited by pressing the Mode/Advance switch for two seconds.
TEACHING THE RECEIVER A TRANSMITTER ADDRESS
If no transmitter is programmed for an address, a new transmitter may be programmed into that
address by activating the desired transmitter. The activated transmitter will then be entered into
that address. The transmitter must be activated by pressing the test button or by causing a
violation transmission to be sent. The SX TX-9x series transmitters are activated by pressing
one of the buttons on the transmitter. Each button that will be used must be programmed as a
separate transmitter. Supervisory, restores, battery low, and tamper transmissions are not
learned.
Based on the type of transmitter received, the receiver will try to set the supervisory and restore
characteristics appropriately for that type of transmitter. These can be changed as desired using
the Set switch.
SX TX-9x series hand-held transmitters are set to non-supervised, restoring. SX TMD-90
motion detectors are set to supervised, non-restoring. All other SX transmitters are set to
supervised, restoring. All S1 transmitters are set to supervised, restoring. All Megacode
transmitters are set to non-supervised, non-restoring.