Advantech PCI-1718 Series Carbon Monoxide Alarm User Manual


 
33 Chapter 3
Analog Output Connection
The PCI-1718HDU/HGU provides one D/A output channel. You can use
the internal precision -5 V or -10 V reference to generate 0 to +5 V or 0 to
+10 V D/A output. Use an external reference for other D/A output ranges.
The maximum reference input voltage is ±10 V and maximum output
scaling is ±10 V. Loading current for D/A outputs should not exceed 5
mA.
Connector CN3 provides D/A signals. Important D/A signal connections
such as input reference, D/A outputs and analog ground appear below:
Figure 3.3: Analog Output Connections
JP10
JP11
-5V
ON-Board
REF
-10V
D/A
CN3-31 D/A REF IN
CN3-30 D/A OUT
CN3-9,10,28,29 A.GND
CN3-11 VREF