ADT Security Services 200 Plus Home Security System User Manual


 
37
System Programming (contd)
6. Press Continue to display the first Burglary (BA) group description. This
screen also shows the user’s access privilege for the BA group displayed
("Can access & open," "Can access," "Can access irr & open," or "Can not
access").
Refer to Table 1: Access Capability later in this section.
Assigning Burglary Group Access
7. To change the user’s access and open privilege to the BA group displayed,
press Change or to display the user’s access privilege to the next BA
group, press Continue.
8. To assign access and open privileges for this user to each BA group,
repeat step 7.
9. Once you have assigned access to all the BA groups (pressing Continue at
the last BA group), the operating panel will automatically display the
Privilege Level Selection Menu.
Assigning Privilege Levels
Once an ID is assigned the user may automatically perform the following
basic functions:
Turn on/off assigned burglary protection.
Test system sounders.
Test burglary points.
View/print the system’s history log.
Note: To change the privilege level of a user, an ID code must have this
capability assigned to it during the initial setup and programming of the
system by ADT.
Each code may also be assigned one or more of the following privilege levels:
Open irregular – Open (turn off) BA group(s) outside of the scheduled
opening time. A user without this privilege level will trip an irregular
opening alarm or be denied access if a BA group is turned off before the
opening time, after the closing time, or on a holiday.